5 years
0 Lacs
HSR Layout, Bengaluru, Karnataka
Posted:1 week ago| Platform:
On-site
Full Time
Radiation Safety Officer (RSO) – QA for DXE The Radiation Safety Officer (RSO) is responsible for ensuring radiation protection and regulatory compliance across the facility. This role also includes direct responsibility for the Quality Assurance (QA) of Diagnostic X-ray Equipment (DXE) as per AERB guidelines. The RSO ensures the safe and optimal use of radiation in all diagnostic imaging practices. Key Responsibilities:1. Radiation Safety & Compliance: Develop and manage a facility-wide Radiation Safety Program in compliance with AERB regulations. Maintain records and manage licensing and regulatory communication via the eLORA portal . Ensure radiation protection practices (shielding, signage, PPE, exposure limits) are in place and enforced. Monitor personnel radiation exposure and ensure all occupational dose limits are within safe thresholds. Conduct radiation safety training for staff, including ALARA principles. 2. Quality Assurance – Diagnostic X-ray Equipment (DXE): Implement and maintain a structured QA Program for all DXE , including CR, DR, CT, Mobile X-rays, and C-arms. Perform acceptance testing , periodic QA , and calibration verification of X-ray machines. Ensure compliance with AERB’s “ Safety Code for Medical Diagnostic X-ray Equipment and Installations .” Record and maintain QA test reports such as: kVp accuracy and reproducibility Timer accuracy Radiation output linearity and reproducibility HVL measurement Image quality checks Leakage and scatter radiation measurements Coordinate with service engineers for corrective actions and documentation of service records. 3. Incident Management & Reporting: Investigate any radiation exposure incidents or QA failures and initiate corrective measures. Submit periodic compliance and QA reports to the management and AERB as required. 4. Equipment & Area Audits: Conduct radiation surveys and leakage testing in controlled and supervised areas. Maintain inventory and compliance records for all radiation-generating equipment. Qualifications: Educational Requirements: M.Sc. in Medical Physics / Radiological Physics OR B.Sc. with Postgraduate Diploma in Radiological Physics (PGDRP) from an AERB-recognized institution Certifications: Must be a certified Radiation Safety Officer (RSO – Level I or II) recognized by AERB, Quality Assurance (QA) of Diagnostic X-ray Equipment (DXE) Experience: 2–5 years in radiation safety and QA of diagnostic imaging equipment Skills & Competencies: In-depth knowledge of AERB safety codes and ICRP radiation protection standards Proficiency in QA testing procedures and use of QA tools (e.g., kVp meter, ion chamber, dosimeters) Excellent report writing and documentation skills Strong communication and training delivery ability Attention to detail and technical troubleshooting skills Work Environment: Hospitals, imaging centers, or facilities using DXE, mobile X-ray units, and CT systems Work involves periodic handling of radiation monitoring equipment, PPE, and QA instruments Job Types: Full-time, Permanent Pay: ₹60,000.00 - ₹80,000.00 per month Benefits: Health insurance Paid sick time Paid time off Provident Fund Schedule: Day shift Monday to Friday Weekend availability Work Location: In person
Remesan Healthcare Pvt Ltd
Upload Resume
Drag or click to upload
Your data is secure with us, protected by advanced encryption.
HSR Layout, Bengaluru, Karnataka
0.6 - 0.8 Lacs P.A.
3.0 - 7.0 Lacs P.A.
15.0 - 25.0 Lacs P.A.
HSR Layout, Bengaluru, Karnataka
0.6 - 0.8 Lacs P.A.