Get alerts for new jobs matching your selected skills, preferred locations, and experience range. Manage Job Alerts
5.0 - 10.0 years
6 - 15 Lacs
Chennai
Work from Office
Good working knowledge on design of control, protection, metering, and monitoring systems for LV/ MV/ HV/ EHV substations from concept design to construction drawings. Working knowledge on T&D functions w.r.t construction in coordination with other engineering disciplines. Working knowledge on control, protection, metering, and monitoring systems pertaining to control & protection schemes, CT/ PT calculations, relay setting calculations etc. Strong Knowledge of SAS system, IED relays, IEC61850, and interface with SCADA and communication Familiar with relevant codes & standards International electro-technical commission (IEC), IEEE, BS (British Standards), Regional Standards, Quality and Metrology Organization (SASO), SEC standards etc. Strong understanding and working knowledge of design software – DIGSI, PCM600, MICOM AGILE, Envista, SEL, Building Designer, MicroStation, AutoCAD etc. Be passionate about protection systems and the power environment. Be a creative leader in design and project management. Have excellent technical skills and be able to mentor staff in their own development and the development of projects. Good communication skills, both in presentation and documentation with a good command over English.
Posted 4 days ago
5 - 10 years
5 - 7 Lacs
Jamnagar, Jaisalmer, Tuljapur
Work from Office
Key Responsibilities: 1 Protection System Design & Coordination: Design, review, and implement protection schemes for 400kV switchyards . Configure and program numerical relays (Siemens, ABB, GE, Schneider, SEL, Alstom, etc.) . Perform relay coordination studies to ensure selectivity and system stability. Develop and implement protection logic diagrams, settings, and interlocking schemes . 2 Testing & Commissioning of Protection Equipment: Conduct testing and commissioning of: Distance Protection (Zonal Protection, Carrier Aided Trip, Power Swing Block) Differential Protection (Transformer, Line, Busbar, Reactor Protection) Overcurrent & Earth Fault Protection Breaker Failure Protection, Synchro-check, and Auto Recloser Relays Perform Primary and Secondary Injection Testing using Omicron, Doble, or Megger test kits. Verify Current Transformer (CT) & Potential Transformer (PT) ratios, polarity, and burden calculations . Conduct circuit breaker timing tests and SF6 gas monitoring . 3 Fault Analysis & Troubleshooting: Analyze fault records, relay event logs, and disturbance reports to identify root causes. Investigate grid disturbances, tripping events, and blackout scenarios . Coordinate with Grid Operators, Load Dispatch Centers (LDCs), and System Control Units for system restoration. 4 Documentation & Compliance: Maintain records of relay settings, test results, and protection coordination reports . Prepare testing & commissioning protocols, SAT (Site Acceptance Test) reports, and relay configuration documents . Ensure compliance with IEC 61850, IS, IEEE, and Grid Code requirements . 5 Safety & Reliability: Ensure adherence to LOTO (Lockout-Tagout) procedures before testing or maintenance. Implement best practices for electrical safety, earthing, and system protection . Conduct risk assessments and ensure reliable protection system operation . Required Qualifications & Skills: Education: B.Tech/B.E. in Electrical Engineering (Diploma holders with relevant experience may apply). Experience: 5-10 years in Protection, Testing & Commissioning of 400kV switchyards . Technical Knowledge: Relay Testing & Coordination (Distance, Differential, Overcurrent, Busbar Protection) Protection Scheme Design (AIS/GIS Substations, Transmission Lines, Transformers) SCADA, Substation Automation (IEC 61850, Goose Messaging, RTU, HMI) Testing Equipment: Omicron, Doble, Megger, Freja Fault Analysis, Grid Protection Studies, Power System Analysis Certifications: Power System Protection, Omicron / Doble Relay Testing Certifications (Preferred). Software Skills: PSCAD, ETAP, DigSILENT, MiCOM S1 Agile, Siemens DIGSI, GE EnerVista. Key Traits: Analytical skills, problem-solving, relay coordination expertise, and system reliability focus . Preferred Experience In: 400kV Switchyard Protection System Design & Testing Transformer, Line, Busbar & Reactor Protection Schemes Numerical Relay Configuration (Siemens, ABB, GE, Schneider, SEL, Alstom) SCADA, Substation Communication (IEC 61850, MODBUS, DNP3) Grid Synchronization, Fault Investigation, Power System Stability
Posted 1 month ago
Upload Resume
Drag or click to upload
Your data is secure with us, protected by advanced encryption.
Browse through a variety of job opportunities tailored to your skills and preferences. Filter by location, experience, salary, and more to find your perfect fit.
We have sent an OTP to your contact. Please enter it below to verify.
Accenture
16951 Jobs | Dublin
Wipro
9154 Jobs | Bengaluru
EY
7414 Jobs | London
Amazon
5846 Jobs | Seattle,WA
Uplers
5736 Jobs | Ahmedabad
IBM
5617 Jobs | Armonk
Oracle
5448 Jobs | Redwood City
Accenture in India
5221 Jobs | Dublin 2
Capgemini
3420 Jobs | Paris,France
Tata Consultancy Services
3151 Jobs | Thane