Get alerts for new jobs matching your selected skills, preferred locations, and experience range. Manage Job Alerts
2.0 - 4.0 years
1 - 4 Lacs
ahmedabad
Work from Office
Responsibilities : Install, maintain, and repair electrical systems, wiring, switchboards, and equipment. Perform preventive and breakdown maintenance of production machinery, HVAC systems, and utility equipment. Monitor and troubleshoot electrical faults in control panels, motors, and PLCs. Ensure compliance with electrical safety standards and GMP practices. Conduct routine checks on UPS, DG sets, transformers, panels, and lighting systems. Maintain records of electrical work, maintenance schedules, and logbooks. Coordinate with production and engineering teams to minimize downtime. Support equipment qualification, validation, and calibration activities. Assist in energy-saving initiatives and ensure proper earthing and power distribution. Required Skills: Logical thinking. Organizing. Good in communication. Required Qualification: - Diploma/B.E/B.Tech - Electrical
Posted Date not available
12.0 - 18.0 years
10 - 14 Lacs
kothur
Work from Office
Primary Role • Knowledge of Machine Maintenance like press machine, VMC and HMC, VTL, HBM. 1. Able to attend to all electrical-related works, cable routing, and machine commissioning. 2. Should be able to handle the breakdowns with the team and individually. 3. Should have 11 kVA or 33 kVA electrical lenience. 4. Liaison with TSPDCL. 5. Awareness of motors, PLC, HMI, ladder drawings, electrical circuits and related works. 6. Awareness of EMS, QMS, and OSHAS Documentation. 7. Awareness on 5S Implementation and Guidance to Supervisor and below. 8. Able to complete the preventive maintenance according to the schedule. 9. Awareness of Safety Precautions while working on electrical works. 10. Should follow up on the logbook records, like DG set diesel consumption, electrical records, daily work details, and spare usage. 11. Knowledge in mechanical-related breakdowns. 12. Should have leadership qualities to lead the team and manage the works. 13. Should have analysis skills to break down the root cause. 14. Should be aware of the criticalness of machinery. 15. Awareness of electrical power distribution-related equipment like DG, transformers, and breakers. 16. Knowledge in identification of cable sizes and electrical spares. 17. Should have to share the knowledge of work with technicians and below workers. 18. Should be implementing Kaizen and horizontal deployment.
Posted Date not available
2.0 - 5.0 years
2 - 3 Lacs
poonamallee, pallavaram, chennai
Work from Office
Dear All, Urgent Hiring for below positions!!! Wanted "Electrical Maintenance - Technician" Location : Pallavaram, Perungudi, Porur, Sholinganallur Exp : 2 to 4 years in electrical Maintenance(HT Site or Building Maintenance) Contact :8939872488 Mail Id: tn.recruiter@gshgroup.com Preferred Immediate Joiners or able to join within 7 days Please refer your friends
Posted Date not available
8.0 - 13.0 years
8 - 14 Lacs
mumbai suburban, navi mumbai, mumbai (all areas)
Work from Office
Responsible for electrical design engineering building services design and cross check the results using hand calculations with experience in an Building Services ( Airports project, Residential , commercial) consultancy and software like AUTO CAD. Required Candidate profile B.tech / M.tech Electrical Engineering with 8 to 12 years' of electrical design experience in Highrise and aviation projects in Building Services consultancy. Exp in Airports must with Auto CAD
Posted Date not available
3.0 - 5.0 years
2 - 6 Lacs
tiruchirapalli
Work from Office
Ensure completion of all schedules and capturing of abnormalities through Schedule monitoring during their watch. Suggesting on Purchase of electrical material as required to Executive technical Maintaining correct tool procedure Responsibilities Read the log book. Check the HSD tank level note down in the log book. Check the LTPCC feeders. And DGs Auto/manual positions Check the all relay position tap changer position. Check up the DG set water level, oil level and check up the specific gravity of battery (weekly once). Battery condition to be monitored. Check up the Transformer oil level (Oil temp, Winding temp, silica gel color) Record the readings twice in shift. Run D.G. on idle run daily once. Check up the capacitor bank always to maintain the unity. Note down the P.F readings in the log book. In 2nd shift at 6pm switch on the utility lights, Chiller plant, out side street lights and total plant lighting operation trouble shooting. Carry out the PM schedules /break downs works rectification on that day programs. Ensure that log sheets are up dated in the same time.
Posted Date not available
2.0 - 3.0 years
2 - 3 Lacs
alathur
Work from Office
(a) General 1. To ensure 100% uptime of HT line and in case of any breakdown to coordinate with concerned persons for the rectification of the faulty line HT line. 2. To ensure the on time preventive maintenance of VCB/SF6 ensuring all safeties are operational. 3. Cleaning Inspection after Racking out of VCB (Complete Panel Shutdown mandatory). 4. Contact Gap Checking. 5. Servicing of draw out mechanism. 6. Replacement of defective parts (VCB Spares to be supplied by the IFMS Provider). 7. Checking of Manual motorized operation of VCB. 8. Contact Timing Checking. 9. Conducting annual preventive maintenance of AVR/Transformer unit including dehydration test. 10. Routine Tests shall be carried out on each unit as per IS: 2026. These tests shall consist of following- (a) Physical Examination (b) Insulation Resistance (c) High Voltage Tests (d) No-Load Current (e) No-Load Losses (f) Load Losses Efficiency (g) Induced Voltage Test (h) Output Voltage Test (i) Provision for earthing (j) Winding Resistance (k) Ratio Polarity test (l) Dielectric strength of oil. Qualifications: Knowledge of Rating and Diagram Plate ; HT Substations, Lifting Lugs, Oil level gauge; Air release plug; Drain cum Filter Valve, Explosion vent pipe, Silica gel breather ; DG Synchronization.'
Posted Date not available
2.0 years
2 - 3 Lacs
alathur
Work from Office
(a) General 1. To ensure 100% uptime of HT line and in case of any breakdown to coordinate with concerned persons for the rectification of the faulty line HT line. 2. To ensure the on time preventive maintenance of VCB/SF6 ensuring all safeties are operational. 3. Cleaning Inspection after Racking out of VCB (Complete Panel Shutdown mandatory). 4. Contact Gap Checking. 5. Servicing of draw out mechanism. 6. Replacement of defective parts (VCB Spares to be supplied by the IFMS Provider). 7. Checking of Manual motorized operation of VCB. 8. Contact Timing Checking. 9. Conducting annual preventive maintenance of AVR/Transformer unit including dehydration test. 10. Routine Tests shall be carried out on each unit as per IS: 2026. These tests shall consist of following- (a) Physical Examination (b) Insulation Resistance (c) High Voltage Tests (d) No-Load Current (e) No-Load Losses (f) Load Losses Efficiency (g) Induced Voltage Test (h) Output Voltage Test (i) Provision for earthing (j) Winding Resistance (k) Ratio Polarity test (l) Dielectric strength of oil. Qualifications: Knowledge of Rating and Diagram Plate ; HT Substations, Lifting Lugs, Oil level gauge; Air release plug; Drain cum Filter Valve, Explosion vent pipe, Silica gel breather ; DG Synchronization.'
Posted Date not available
Upload Resume
Drag or click to upload
Your data is secure with us, protected by advanced encryption.
Browse through a variety of job opportunities tailored to your skills and preferences. Filter by location, experience, salary, and more to find your perfect fit.
We have sent an OTP to your contact. Please enter it below to verify.
Accenture
73564 Jobs | Dublin
Wipro
27625 Jobs | Bengaluru
Accenture in India
22690 Jobs | Dublin 2
EY
20638 Jobs | London
Uplers
15021 Jobs | Ahmedabad
Bajaj Finserv
14304 Jobs |
IBM
14148 Jobs | Armonk
Accenture services Pvt Ltd
13138 Jobs |
Capgemini
12942 Jobs | Paris,France
Amazon.com
12683 Jobs |